Customization: | Available |
---|---|
Usage: | Light |
Output Type: | Single |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Meanwell ELG-100 Series 100W 24V Power Supply ELG-100-24 ELG-100-24A ELG-100-24B LED Driver
Features:
Constant Voltage + Constant Current mode output
Metal housing design with functional Ground
Built-in active PFC function
Class 2 power unit
No load / Standby power consumption <0.5W
lP67 / lP65 rating for indoor or outdoor installations
Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off); Smart timer dimming; DALl
Typical lifetime>50000 hours
5 years warranty
MODEL | ELG-100-24 | ELG-100-36 | ELG-100-42 | ELG-100-48 | ELG-100-54 | |||
OUTPUT |
DC VOLTAGE | 24V | 36V | 42V | 48V | 54V | ||
CONSTANT CURRENT REGION Note.2 | 12 ~ 24V | 18 ~ 36V | 21 ~ 42V | 24 ~ 48V | 27 ~ 54V | |||
RATED CURRENT | 4.0A | 2.66A | 2.28A | 2A | 1.78A | |||
RATED POWER |
200VAC ~ 305VAC | |||||||
96W | 95.76W | 95.76W | 96W | 96.12W | ||||
100VAC ~ 180VAC | ||||||||
70W | 70W | 70W | 70W | 70W | ||||
RIPPLE & NOISE (max.) Note.3 | 200mVp-p | 250mVp-p | 250mVp-p | 300mVp-p | 350mVp-p | |||
VOLTAGE ADJ. RANGE | Adjustable for A/AB-Type only (via the built-in potentiometer) | |||||||
21.6 ~ 26.4V | 32.4 ~ 39.6V | 37.8 ~ 46.2V | 43.2 ~ 52.8V | 48.6 ~ 59.4V | ||||
CURRENT ADJ. RANGE | Adjustable for A/AB-Type only (via the built-in potentiometer) | |||||||
2 ~ 4A | 1.33 ~ 2.66A | 1.14 ~ 2.28A | 1 ~ 2A | 0.89 ~ 1.78A | ||||
VOLTAGE TOLERANCE Note.4 | ±3.0% | ±2.5% | ±2.5% | ±2.0% | ±2.0% | |||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
LOAD REGULATION | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |||
SETUP, RISE TIME Note.6 | 1000ms, 80ms/115VAC 500ms, 100ms/230VAC | |||||||
HOLD UP TIME (Typ.) | 15ms/115VAC 10ms/230VAC | |||||||
INPUT |
VOLTAGE RANGE | Note.5 | 100 ~ 305VAC 142 ~ 431VDC continue,320VAC for 24Hrs; 360VAC for 1Hr (Please refer to "STATIC CHARACTERISTIC" section) |
|||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
POWER FACTOR | PF>=0.97/115VAC, PF>=0.95/230VAC, PF>=0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) |
|||||||
TOTAL HARMONIC DISTORTION | THD< 20%(@load>=50%/115VC; @load>=60%/230VAC; @load>=75%/277VAC) (Please refer to "TOTAL HARMONIC DISTORTION(THD)" section) | |||||||
EFFICIENCY (Typ.) | 88% | 89% | 90% | 90% | 91% | |||
AC CURRENT | 1.1A / 115VAC 0.6A / 230VAC 0.5A/277VAC | |||||||
INRUSH CURRENT(Typ.) | COLD START 60A(twidth=850μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |||||||
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC | |||||||
LEAKAGE CURRENT | <0.75mA / 277VAC | |||||||
NO LOAD / STANDBY POWER CONSUMPTION | No load power consumption <0.5W for Blank / A / Dx / D2-Type Standby power consumption <0.5W for B / AB / DA-Type | |||||||
PROTECTION |
OVER CURRENT | 95 ~ 108% | ||||||
Constant current limiting, recovers automatically after fault condition is removed | ||||||||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 28 ~ 34V | 41 ~ 48V | 47 ~ 54V | 54 ~ 62V | 62 ~ 72V | |||
Shut down output voltage, re-power on to recover | ||||||||
OVER TEMPERATURE | Shut down output voltage, re-power on to recover | |||||||
ENVIRONMENT |
WORKING TEMP. | Tcase=-40 ~ +90ºC (Please refer to " OUTPUT LOAD vs TEMPERATURE" section) | ||||||
MAX. CASE TEMP. | Tcase=+90ºC | |||||||
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |||||||
STORAGE TEMP., HUMIDITY | -40 ~ +80ºC, 10 ~ 95% RH | |||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 60ºC) | |||||||
VIBRATION | 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes | |||||||
SAFETY & EMC |
SAFETY STANDARDS |
UL8750(type"HL"), CSA C22.2 No. 250.13-12; IEC/BS EN/EN/AS/NZS 61347-1, IEC/BS EN/EN/AS/NZS 61347-2-13 independent, BS EN/EN62384; EAC TP TC 004;BIS IS15885(for 24/24A/24B/24DA/36/36A/36B/42/42A/42ADA/42B/48/48B/54/54A/54ADA/54B only); GB19510.1, GB19510.14; IP65 or IP67;KC61347-1,KC61347-2-13 approved |
||||||
DALI STANDARDS | Compliance to IEC62386-101,102,(207 by request) for DA Type only | |||||||
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC | |||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||
EMC EMISSION | Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load>=60%); BS EN/EN61000-3-3;GB17743, GB17625.1; EAC TP TC 020; KC KN15,KN61547 | |||||||
EMC IMMUNITY | Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV); EAC TP TC 020; KC KN15,KN61547 |
|||||||
OTHERS |
MTBF | 2920.8K hrs min. Telcordia SR-332 (Bellcore) 282.9Khrs min. | MIL-HDBK-217F (25ºC) | |||||
DIMENSION | 199*63*35.5mm (L*W*H) | |||||||
PACKING | 0.85kg; 16pcs/14.2kg/0.72CUFT |